For the complete documentation index, see llms.txt. This page is also available as Markdown.

Error handling

Whenever a request to the Dedicated Networks API fails, the response tells you what went wrong in a machine-readable way. This page describes the shape of an error response; the full list of codes is on Error codes.

Error response structure

Every error response from the Dedicated Networks API has the content type application/problem+json (RFC 9457) and this structure:

Property
Value type
Description

title

string

Short, human-readable summary of the problem type.

status

int

The HTTP status code of the response.

detail

string

Human-readable explanation of this specific occurrence. Safe to show to a user.

code

string

Stable machine-readable error code: E followed by six digits, for example E020001.

traceId

string

Identifier of the request. Quote it when you contact i3D.net support.

Table 1: Error response structure

The same traceId value is also sent in the X-Request-Id response header of every response, successful or not, so it is available even when there is no body.

Error response example

{
  "title": "Validation failure",
  "status": 422,
  "detail": "a public network requires explicit addressing.prefixes[] (family and size) - there is no default public prefix",
  "code": "E020001",
  "traceId": "0af7651916cd43dd8448eb211c80319c"
}

Working with error codes

  • Key your error handling off code, not off detail. Codes are stable: a code's meaning never changes. The detail text may be reworded.

  • New codes may be added over time. Treat an unknown code as a generic failure of its HTTP status.

  • Errors from systems behind the API are mapped into this shape and never passed through. i3D.net can find the full detail in its logs using the traceId.

HTTP status codes

Status
Meaning
What to do

400

The request names an unknown filter field, or a known field with an unsupported operator.

Fix the query; the detail lists the supported filters.

401

Your API key is missing or not valid.

Check the PRIVATE-TOKEN header and your IP whitelisting. See the note below.

404

The resource does not exist on your account, belongs to another account, or was deleted. The API never confirms that someone else's resource exists.

Check the UUID. After a completed delete, 404 is the expected answer.

409

The request is correct but the current state does not allow it: a UUID replayed with a different body, a delete blocked by addresses in use, a limit reached, a missing contract, a resource that i3D.net manages, or an edit while an operation is still pending.

Read the code. The same request may succeed once the state has changed.

422

The request body or a query value fails validation. The request can never succeed as written.

Fix the request; the detail names the field or value.

500

Something went wrong on the i3D.net side.

Retry later. If it persists, contact support with the traceId.

Table 2: HTTP status codes

Authentication errors look different. A request without a valid API key is stopped before it reaches the Dedicated Networks API, and the answer is a plain JSON object rather than a problem response:

Treat any 401 as "fix the API key", whatever the body looks like.

Asynchronous failures

A create or delete that was accepted (202) can still fail later. That failure is not an HTTP error: the operation resource reports state: failed together with an error object, and a failed network or prefix shows the same error on its own representation.

Property
Description

error.code

Stable code in SCREAMING_SNAKE_CASE. The list is on Error codes.

error.message

Human-readable message, safe to display.

error.retryable

Whether repeating the request may succeed. Sent on the operation resource only.

Table 3: Operation error structure

When a create fails, the resource stays visible in state failed. Delete it and create a new one with a new UUID. When a delete fails, repeat the DELETE: it continues the teardown.

Retrying safely

  • GET requests can always be retried.

  • PUT creates can be retried with the same UUID and the same body: a replay is answered with the same operation and never creates a duplicate.

  • DELETE can be repeated: it continues a running or failed teardown, and answers 404 once the teardown has completed.

  • On 500, retry the same request after a short wait. If it persists, contact support with the traceId.

Response headers

Every representation carries a strong ETag header. Every response, successful or not, carries an X-Request-Id header. Quote that value when you contact i3D.net support: it is how we find your request. On error responses the same value is in the traceId field of the body.

Last updated

Was this helpful?