For the complete documentation index, see llms.txt. This page is also available as Markdown.

Error codes

Every error response of the Dedicated Networks API carries a stable code. This page lists the codes the Dedicated Networks API can return; the pages they link to state the cause and the fix. For the structure of an error response, see Error handling.

Codes are stable: a code's meaning never changes, and the digits carry no meaning of their own. New codes may be added over time, so treat an unknown code as a generic failure of its HTTP status.

Request error codes

These codes appear in the code field of an application/problem+json error response. Each code links to its page in the error registry, which states the likely causes and how to resolve it.

Code
Status
Title
Summary

422

Validation failure

The request was parsed, but a field or a query value is not acceptable.

404

Resource not found

No network, prefix, operation or IP address with this UUID exists on your account.

409

Idempotency conflict

The UUID in the PUT path already denotes a network or prefix, and the request cannot be treated as a replay.

409

Delete blocked by IP addresses in use

The network cannot be deleted because IP addresses are still in use under its prefixes.

422

Unknown fabric identifier

The fabric value is not one of the fabrics the API currently offers.

500

Internal error

The request could not be completed because of a failure on the i3D.net side.

409

Network not ready

The network named in a prefix create cannot take a prefix in its current state.

400

Unknown filter field

A listing was called with a filter it does not support.

409

Delete blocked by IP addresses in use

The prefix cannot be deleted because your IP addresses are still in use under it.

401

Unauthorized

The identity of the caller could not be established, so the request was not processed.

409

Quota exceeded

The create would take your account past one of its limits.

409

Contract required

Creating networks and prefixes on this account requires a contract with i3D.net, and none covers it.

409

Contract required to remove

Deleting networks and prefixes you created yourself requires a contract with i3D.net, and none covers it.

409

Resource is managed by i3D.net

The network or prefix was set up by i3D.net on your behalf, and i3D.net owns its lifecycle.

405

Method not allowed

The path exists but does not support the request method.

409

Operation pending

The prefix cannot be edited while an operation is still pending on it.

Table 1: Request error codes of the Dedicated Networks API

Operation failure codes

These codes appear in error.code of an operation (GET /networks/{networkId}/operation, GET /prefixes/{prefixId}/operation) whose state is failed, and on a network or prefix whose state is failed. They describe why an accepted create or delete did not complete. The set is not closed: treat an unknown code as a generic failure.

Code
Meaning
What to do

NETWORK_PROVISIONING_FAILED

Shown in the error of a network whose provisioning failed. The operation resource carries the more specific code.

Read the network's operation for the specific code and the retryable hint. Delete the network and create a new one with a new UUID.

NETWORK_BOOTSTRAP_FAILED

Provisioning the network did not complete. Whatever was created before the failure (for example some of the initial prefixes) stays visible on the failed network.

Delete the network and create a new one with a new UUID. If it happens again, contact support with the X-Request-Id of the create.

NETWORK_TEARDOWN_FAILED

Deleting the network did not complete. The network keeps the state it had before the delete.

Repeat the DELETE; it continues the teardown where it stopped. If it keeps failing, contact support.

VLAN_NETWORK_CONFIGURATION_FAILED

Applying the configuration of the network segment on the i3D.net network did not complete.

Delete the network and create a new one with a new UUID. If it happens again, contact support.

PREFIX_ADDRESSING_FAILED

An address block for a prefix added to an existing network could not be reserved or verified.

Delete the prefix and create a new one with a new UUID. If it happens again, contact support.

PREFIX_NETWORK_CONFIGURATION_FAILED

Applying the prefix's configuration on the i3D.net network did not complete.

Delete the prefix and create a new one with a new UUID. If it happens again, contact support.

PREFIX_NOT_PROVISIONED

The network operation that owned this prefix ended without leaving the prefix provisioned: the network's provisioning failed, or the network was torn down. Never retryable on the prefix itself.

Act on the network: delete it and create a new one if its provisioning failed. There is nothing to retry on the prefix.

PREFIX_TEARDOWN_FAILED

Deleting the prefix did not complete.

Repeat the DELETE; it starts the teardown again and finishes what is left. If it keeps failing, contact support.

Table 2: Operation failure codes

Getting help

If an error does not resolve, contact i3D.net support and include the traceId (or the X-Request-Id header) of the failing request, the UUID of the resource, and the fabric. The traceId is how we find your request.

Last updated

Was this helpful?