For the complete documentation index, see llms.txt. This page is also available as Markdown.

E020003

Idempotency conflict

HTTP status: 409

Returned by: Dedicated Networks API, PUT /networks/{networkId}, PUT /prefixes/{prefixId}.

What happened

The UUID in the PUT path already denotes a network or prefix, and the request cannot be treated as a replay. Nothing was changed.

Likely causes

  • The same UUID was sent with a different body. PUT only ever creates; it never replaces or updates an existing resource.

  • On a prefix: the UUID has a delete in progress or a failed delete. A deleted identity is never re-created, and the body is not even compared.

How to resolve it

  • To create another network or prefix, generate a new UUID v7 and send the request again.

  • To replay a create after a timeout, send exactly the same body as the first time. An identical replay answers 202 with the same operation and creates nothing new.

  • To change a network, make day-2 changes one resource at a time, for example by adding a prefix. There is no update of a network or prefix.

Example response

Last updated